Home › Codes › SPN 168 › FMI 2

SPN 168 FMI 2

Battery Potential / Power Input 1 — Data erratic, intermittent, or incorrect.
The signal jumps around, drops in and out, or disagrees with other information the controller has.

What the SPN covers: Voltage the engine computer sees on its main power supply. More on SPN 168.

What FMI 2 usually points to: Loose or corroded connectors, chafed wiring, a failing sensor, or two redundant sensors that do not agree. More on FMI 2.

Severity

MEDIUM — fix soon

Low or unstable voltage can cause many unrelated codes and no-starts. Fix power first.

Likely causes

  1. Weak batteries
  2. Loose or corroded battery cables
  3. Charging system fault (alternator)
  4. Bad ECM power or ground connection

Checks & fixes (easiest first)

  1. Load-test batteries
  2. Clean and tighten battery and ground cables
  3. Check charging voltage at the alternator and at the ECM
  4. Voltage-drop test the ECM power and ground circuits

FAQ

What does SPN 168 FMI 2 mean?

Battery Potential / Power Input 1 — data erratic, intermittent, or incorrect. The signal jumps around, drops in and out, or disagrees with other information the controller has.

Is SPN 168 FMI 2 serious?

Low or unstable voltage can cause many unrelated codes and no-starts. Fix power first.

What should I check first for SPN 168 FMI 2?

Load-test batteries; Clean and tighten battery and ground cables; Check charging voltage at the alternator and at the ECM.