Home › Codes › SPN 639 › FMI 9
SPN 639 FMI 9
J1939 Network #1 (Primary Data Link) — Abnormal update rate.
Expected data is arriving too slowly or has stopped arriving over the data link.
What the SPN covers: The main J1939 CAN data link that modules use to talk to each other. More on SPN 639.
What FMI 9 usually points to: A module that has dropped offline, a network wiring issue, or a module that is overloaded or resetting. More on FMI 9.
Severity
MEDIUM — fix soon
Can cause many modules to lose data, dash gauges to drop, and derates.
Likely causes
- Missing or failed terminating resistor
- Shorted or open CAN wires
- A failed module dragging the bus down
- Damaged diagnostic connector or aftermarket device
Checks & fixes (easiest first)
- Check for other network codes and the module that sends this data
- Inspect the J1939 backbone and terminating resistors
- Measure resistance across CAN high/low at the diagnostic port (key off, about 60 Ω expected)
- Unplug modules one at a time to find a bad one
- Inspect for chafed twisted pair
- Remove aftermarket devices on the bus
FAQ
What does SPN 639 FMI 9 mean?
J1939 Network #1 (Primary Data Link) — abnormal update rate. Expected data is arriving too slowly or has stopped arriving over the data link.
Is SPN 639 FMI 9 serious?
Can cause many modules to lose data, dash gauges to drop, and derates.
What should I check first for SPN 639 FMI 9?
Check for other network codes and the module that sends this data; Inspect the J1939 backbone and terminating resistors; Measure resistance across CAN high/low at the diagnostic port (key off, about 60 Ω expected).